Difference between revisions of "2014 S Workshop Topics"
(5 intermediate revisions by the same user not shown) | |||
Line 15: | Line 15: | ||
| R. Nouvel <br/> (HFT - energy) || Review of urban energy simulation models and their data requirements >> [[File:Nouvel_Urban_Energy_Simulation.pdf]] | | R. Nouvel <br/> (HFT - energy) || Review of urban energy simulation models and their data requirements >> [[File:Nouvel_Urban_Energy_Simulation.pdf]] | ||
|- | |- | ||
− | | Dr. Perez <br/> (former EPFL) || Issues and challenges specific to urban energy models >> [[File:. | + | | Dr. Perez <br/> (former EPFL) || Issues and challenges specific to urban energy models >> [[File:Diane_Perez_CityGML_workshop_Stuttgart.pdf]] |
|- | |- | ||
| K.-H. Haefele <br/> (KIT) || IFC and gbXML, 2 Building information models for building performance simulation >> [[File:Haefele_IFC-gbXML-V2.pdf]] | | K.-H. Haefele <br/> (KIT) || IFC and gbXML, 2 Building information models for building performance simulation >> [[File:Haefele_IFC-gbXML-V2.pdf]] | ||
Line 27: | Line 27: | ||
|- | |- | ||
| '''Draft Energy ADE of TU München''' >> [[File:EnergyADE_TU-Muenchen.pdf]] | | '''Draft Energy ADE of TU München''' >> [[File:EnergyADE_TU-Muenchen.pdf]] | ||
− | + | [[File:UMLdiagramm_ADE_Energy_TU_Munchen.png|right|300px|EnergyADE proposal of the TU Munich]] | |
* Main features of this ADE Energy | * Main features of this ADE Energy | ||
− | This Energy ADE is "ENEV-conform" (ENEV = German thermal regulation). The present scope is only the calculation of space heating and cooling demand </ | + | This Energy ADE is "ENEV-conform" (ENEV = German thermal regulation). The present scope is only the calculation of space heating and cooling demand <br/> |
Modelling decision: The thermal hull is modelled separately from the existing boundary surfaces of CityGML, so as to be fully independant of the CityGML LOD and be able to modell complex thermal hull (attic storey and cellar partly heated etc.) | Modelling decision: The thermal hull is modelled separately from the existing boundary surfaces of CityGML, so as to be fully independant of the CityGML LOD and be able to modell complex thermal hull (attic storey and cellar partly heated etc.) | ||
The data modell follows fully the required inputs from the ENEV algorithm (8 facade surface area for the orientations N, NE, E, SE etc...). | The data modell follows fully the required inputs from the ENEV algorithm (8 facade surface area for the orientations N, NE, E, SE etc...). | ||
* Remarks of the audience: | * Remarks of the audience: | ||
− | Why | + | Why don't you keep the full information concerning the boundary surface orientations? <br/> |
− | Why should the ADE Energy be restricted to | + | Why should the ADE Energy be restricted to this German regulation? |
|- | |- | ||
| '''Draft Energy ADE of project SimStadt''' >> [[File:EnergyADE_SimStadt.pdf]] | | '''Draft Energy ADE of project SimStadt''' >> [[File:EnergyADE_SimStadt.pdf]] | ||
− | + | [[File:Uml-energy-ade.png|right|350px|HFT Stuttgart UML Energy ADE]] | |
* Main features of this ADE Energy | * Main features of this ADE Energy | ||
This Energy ADE is designed first for steady state simulation (yearly, monthly balance) but may be extended for dynamical simulation (hourly time step). The present scope is only the calculation of space heating / cooling and domestic hot water demand <br/> | This Energy ADE is designed first for steady state simulation (yearly, monthly balance) but may be extended for dynamical simulation (hourly time step). The present scope is only the calculation of space heating / cooling and domestic hot water demand <br/> | ||
Line 55: | Line 55: | ||
* Modelling of Building Physics, HVAC Systems inside the building (geometrical information not necessary), HVAC controls and set-points, Building usage and occupants (maybe later outsourced into a Building Occupant ADE). | * Modelling of Building Physics, HVAC Systems inside the building (geometrical information not necessary), HVAC controls and set-points, Building usage and occupants (maybe later outsourced into a Building Occupant ADE). | ||
* should allow a plurality of building simulation models adapted to city scale (steady state energy balance, simplified dynamical simulation etc.) | * should allow a plurality of building simulation models adapted to city scale (steady state energy balance, simplified dynamical simulation etc.) | ||
− | * | + | * The ADE Energy of CityGML should be a BIM like IFC, but in comparison to the latter format, it should tackle city scale energy issues, considering not only the buildings but also energy infrastructure, urban forms, streets, vegetations and other urban objects. |
|- | |- | ||
| Modelling of Energy infrastructure (District Heating System etc.)? | | Modelling of Energy infrastructure (District Heating System etc.)? | ||
− | * For the modelling of urban energy network, it exists already specific data model of network simulation softwares and the ADE Utility network | + | * For the modelling of urban energy network, it exists already data modell (specific data model of network simulation softwares and the ADE Utility network, which could be soon integrated into the CityGML 3.0). Then, no urban energy infrastructure modelling is necessary into the ADE Energy (which focus on Building energy). For the connection between the ADE Energy and the network modell, connection points (network substations and heat exchangers) are necessary to link the buildings with specified networks. |
|- | |- | ||
| Which parameters should we store for the HVAC systems in CityGML, so as to match the different data requirements of the different HVAC models? | | Which parameters should we store for the HVAC systems in CityGML, so as to match the different data requirements of the different HVAC models? | ||
Line 72: | Line 72: | ||
|- | |- | ||
| | | | ||
− | * Group '''Building Physics and Materials''' : K-H Häfele, R. Kaden, M. Lauster, R. Nouvel | + | * Group '''Building Physics and Materials''' : K-H Häfele, R. Kaden, M. Lauster, S. Mohamed, R. Nouvel |
Synchronised with development of CityGML 3.0 on Materials. | Synchronised with development of CityGML 3.0 on Materials. | ||
* Group '''HVAC systems and urban energy infrastructure''' : R. Nouvel, E. Duminil, D. Monien, M. Lauster, D. Perez | * Group '''HVAC systems and urban energy infrastructure''' : R. Nouvel, E. Duminil, D. Monien, M. Lauster, D. Perez |
Latest revision as of 12:44, 1 July 2014
1st Workshop ADE Energy - Stuttgart, 27th of May 2014
- Host: Hochschule für Technik - Stuttgart
- Participant list >> File:Participant list.pdf
Morning Presentations
Presenters (Organisation) | Presentations |
---|---|
Prof. Dr. Coors (HFT - geoinformatics) |
CityGML and its existing building model >> File:Coors Energy ADE Intro.pdf |
R. Nouvel (HFT - energy) |
Review of urban energy simulation models and their data requirements >> File:Nouvel Urban Energy Simulation.pdf |
Dr. Perez (former EPFL) |
Issues and challenges specific to urban energy models >> File:Diane Perez CityGML workshop Stuttgart.pdf |
K.-H. Haefele (KIT) |
IFC and gbXML, 2 Building information models for building performance simulation >> File:Haefele IFC-gbXML-V2.pdf |
Afternoon Discussion
First proposals Energy ADE |
Draft Energy ADE of TU München >> File:EnergyADE TU-Muenchen.pdf
This Energy ADE is "ENEV-conform" (ENEV = German thermal regulation). The present scope is only the calculation of space heating and cooling demand
Why don't you keep the full information concerning the boundary surface orientations? |
Draft Energy ADE of project SimStadt >> File:EnergyADE SimStadt.pdf
This Energy ADE is designed first for steady state simulation (yearly, monthly balance) but may be extended for dynamical simulation (hourly time step). The present scope is only the calculation of space heating / cooling and domestic hot water demand
Where do you store your simulation results or measured consumption data? Answer: in the EnergyUse class. |
Open discussion |
What is the scope of the ADE Energy?
|
Modelling of Energy infrastructure (District Heating System etc.)?
|
Which parameters should we store for the HVAC systems in CityGML, so as to match the different data requirements of the different HVAC models?
|
Should we import/convert/store everything into CityGML?
|
Working groups |
Synchronised with development of CityGML 3.0 on Materials.
See also projects "extra-Energy" around. May lead to a "Building occupant ADE".
|